View RTI Configuration

Unified Glossary

Basics of using a Ramco iEnterprise Series 4.0  Web Page

Using Online Help

This page allows you to view the details of the configuration of the Real Time Integration system. Tell me more.

The “View RTI Configuration” page appears.

To search for a RTI configuration

Update On

Use the drop-down list box to specify whether you wish to view the real time integration for equipment or a location. The system provides the options: “Equipment” and “Location”. The system displays “Equipment” by default.

Status

Use the drop-down list box to specify the status of the maintainable object. The system provides the options: “Active” and “Inactive”. Leave the field blank to retrieve the real time integration configuration of all equipment or locations irrespective of the status. The system leaves the field blank by default.

Classification

The classification to which the equipment or location belongs (Alphanumeric, 30). You can enter the classification in full or specify it partially. The system retrieves the real time integration configuration of all equipment or locations which belong to similar classifications.

Code

The identifier of the equipment or location for which you wish to view the real time integration configuration (Alphanumeric, 30). You can enter the code in full or specify it partially. The system retrieves the real time integration of all equipment or locations with codes similar to the code specified here.

Desc.

The description of the equipment or location entered in the “Code” field (Alphanumeric, 150). You can enter the description in full or specify it partially. The system retrieves the real time integration of all equipment or locations with descriptions similar to the description entered here.

Location

The location of the equipment (Alphanumeric, 30). You can enter the location in full or specify it partially. The system retrieves the real time integration of all equipment that are associated with a location that is similar to the location entered here.

Parameter

The parameter of the equipment or location for which you wish to view the real time configuration (Alphanumeric, 30). You can enter the parameter in full or specify it partially. The system retrieves the real time integration configuration of all equipment or locations whose parameters are similar to the parameter entered here.

Inspection Point

The inspection point of the equipment or location (Alphanumeric, 30). You can enter the inspection point in full or specify it partially. The system retrieves the real time integration configuration of all equipment or locations to which inspection points similar to the inspection point entered here, are attached.

The system retrieves the following details in the “Search Results” multiline:

Code

The equipment or location retrieved by the system.

Desc.

The description of the equipment or location.

Inspection Point

The inspection point attached to the equipment or location.

Parameter

The parameter for which value is updated from the RTI.

Parameter Type

The type of the parameter, which can be Attribute”, “Consumption” or “Range”.

UOM

The unit of measurement of the parameter.

RTITag   (Pseudonym)  

The tag of the RTI where value is captured.

Measurement

The type of measurement, which can be “Digital” or “Analog”.

Tag UOM

The unit of measurement in which the tag value is updated.

Delta / New

Indicates whether the value updated to the parameter is a new value or an incrementing value. The system displays one of the following:

 

Delta - Indicates that the value updated to the parameter is an incrementing value.

 

New - Indicates that the value updated to the parameter is a new value that replaces the existing value.

Sampling Interval

The time intervals for which parameter values are required from the RTI.

Update When?

The circumstance in which the parameter value must be updated. The system displays one of the following:

 
  • Value Change - Indicates that the parameter value must be updated only when there is a change in the previous updated value.

 
  • Always - Indicates that the parameter value must be updated irrespective of whether there is a change in the previous value or not.

Parameter Value – Event Low

For an attribute parameter, this field indicates the value that would be updated for a digital signal of “0”.

 

For range and consumption parameters, this field indicates the value crossing which the parameter value will receive an update from the RTI.

Parameter Value – Event High

For an attribute parameter, this field indicates the value that would be updated for a digital signal of “1”.

 

For range and consumption parameters, this field indicates the value reaching which the parameter value will receive an update from the RTI.

Off Line?

Indicates whether the parameter value must be updated or not. The system displays “Yes” or “No”.

Remarks

Any additional information about the parameter update from the RTI.

To proceed, carry out the following

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Viewing real time integration configuration – An overview

View RTI Configuration - A summary of the activity

This page allows you to view the details of the configuration of the Real Time Integration system. You can select the equipment – inspection point – parameter combination for which you wish to view the configuration by carrying out a search based on the following fields:

The system retrieves the following details of the parameters, which are updated from the RTI.