Edit Product Structure

Unified Glossary

Basics of using Ramco Enterprise series web page

Using online help

This page allows you to modify the product structure details. Tell me more

The “Edit Product Structure” page appears.

PS No.

The unique number identifying the product structure. Mandatory.

 

Press <Enter> Key.

 

The system checks if the PS number is left blank. If it is left blank, then the validations are not performed. If it is not left blank, then the validations for the PS number are performed and the corresponding PS details are retrieved. The product structure should exist in the product structure master. The system retrieves the Business Unit for the “Maintained By” control unit of the product structure from the “Organization Model” business component. If the Business Unit is same as that of the login Organization Unit, then the system does not display an error message. Otherwise, displays an error message. The system retrieves the multiline details in ascending order of the PS sequence and option sequence. The system retrieves the Organization Unit defined in the “Item Administration” business component mapped to the warehouse Organization Unit of the product structure.

 

Help facility available.

Note: Product Structure defines the single level bill of material that illustrates the relationship between different input and output items, co-products and by-products. Single level Bill of Material is termed as "Product Structure".

PS Desc.

The description of the product structure.

 

Zoom facility available.

Status

Use the drop down list box to select the appropriate status of the product structure.  Mandatory. You can select from “Active”, “Draft” or “Inactive”. The system displays the default value based on the default set through the save template field. Otherwise, the system displays “Active” by default on launch of the page. This field should not be left blank.

 

  • Active – indicates a valid product structure.

 

  • Draft – indicates an incomplete product structure.

 

  • Inactive – indicates an invalid product structure.

The system displays the following:

Plant

 The plant of the warehouse where the item is identified. The plant corresponding to the warehouse gets displayed.

Enter the following details:

Item Code

The code identifying the item for which the product structure has been defined. The system retrieves the primary output item of the product structure. Mandatory.

 

Press <Enter> key.

 

The item code should not be left blank. If the variant is not left blank, then the item code and variant combination should be valid and should be in “Active” status. In both the cases, the system finds the Organization Unit defined in the “Item Administration” business unit is mapped to the login Organization Unit from the “CIM Model” business component. The system also checks for the existence of the item in the “Item Administration” business component. The Organization Unit of the “Process Model” should be mapped to the Organization Unit of the “Item Administration” business component. If the mapping does not exist then the system displays an error message.

 

Help facility available.

 

Note: The output item/item and variant combination should not be changed for a product structure. If the item/item and variant combination specified is different from the output item/ item and variant combination for which the product structure had been originally defined, then the system displays an error message.

Variant Code

The number identifying the variant of the item. The system retrieves the item details for the given item code and variant (if any). If the item does not have a variant, then the system retrieves the item details for the specified item. If the item has a variant, then the system retrieves the item details for the item and variant combination. If the item has more than one variant and the variant is not specified, then the system retrieves only the item description.

The system displays the following:

Desc.

The description of the item–variant combination.  The system retrieves the description for the item and variant combination from the “Item Administration” business component.

 

Zoom facility available.

Note: If help on item code was taken, then the system retrieves the description along with the item code. 

Maintained By

Use the drop-down list box to select the “Maintained By” control units for which the login user has “Transaction” and/or “View” access permission. Mandatory. The system retrieves the control units from the “Organization Model” business component. The system displays the default value based on the value saved through the save template field. Otherwise, the system displays the “Default Maintained By” defined for the login user If neither the default “Maintained By” or the default through the save template field exist, then the system displays the first value as the default value.

The system displays the following:

PS Usage

The usage of the product structure. It can be “Standard”, “Alternate1”, “Alternate2”, “Alternate3”, “Alternate4” or “Alternate5”.

PS Category

 The category of the product structure. “Production”, “Costing”, “Engineering” or “Sub-Contracting”, “Purchase” or “Re-Work”.

Warehouse Code

The warehouse where the supplies for the output items is raised. Mandatory. If the item does not have a variant or has only one variant, then the system retrieves the standard warehouse for the item/item variant.

 

Help facility available.

Note: If PS category is set to “Engineering”, then the warehouse can be left blank

Parent Qty.

The quantity of the primary output item. The quantity of input items required is then defined for producing this quantity. Parent quantity should be greater than "Zero". Mandatory.

The system displays the following:

UOM

 The unit of measurement of the product structure.

Enter the following details:

Process Plan No.

The number identifying the process plan. If process plan is specified, then bill of resource must not be specified. Process plan entered should exist and should be in “Active” status.

 

Help facility available.

Note: The process plan is mapped onto a product structure to establish a manual link.

Bill Of Resource

The number identifying the bill of resource. A bill of resource indicates the sequence of activities used for production of output items. The list of required capacity on key resources needed to manufacture a unit of selected item. If bill of resource is specified, then process plan number must not be specified. Bill of resource entered should exist and should be in “active” status.

 

Help facility available.

Default For

Use the drop down list box to select the default to be set when the product structure is created. You can select from “MRP&Rollup”, “Rollup”, “MRP” or “Blank”. The system displays the default value based on the default set through the save template field. Otherwise, the system displays “MRP” by default on launch of the page. The options available are

 

  • Blank – indicates a blank value.

 

  • MRP&Rollup – indicates the product structure that is defaulted as the product structure to be used when MRP and Rollup is run.

 

  • Rollup – indicates the product structure that is defaulted as the product structure to be used when Rollup is run.

 
  • MRP – indicates the product structure that is defaulted as the product structure to be used when MRP is run.

PS Seq.

The sequence number that identifies the item position in the product structure. Mandatory

Note: The sequence number is defined by the system during the creation of product structure. You can also define the sequence number for the input items during creation. Further if the field is left blank, the system calculates the PS Seq No automatically by taking the last highest value plus the incriminator. Repeated sequence numbers can also be defined.

Item Code

The code identifying the input item. Mandatory

 

Press <Enter> key.

 

For all selected rows, the item should not be left blank. If the variant is left blank, then the item should be valid and should be in “Active” status. For all selected rows, the system retrieves the item details for the given item code and variant (if any). If the item does not have a variant, then the system retrieves the item details for the specified item. If the Item has a variant, then the system retrieves the item details for the item and variant combination. If the item has more than one variant and the variant is not specified, then the system retrieves only the item description.

 

Help facility available.

Variant Code

The code or number identifying the variant of the input item.

The system displays the following in the ”Component Details” multiline:

Desc.

The description in the combination of the item/item variant. 

Quantity

The quantity of the input or secondary output items. The system displays the quantity defined for the input items in the product structure. If quantity is specified, it should be greater than zero.

The system displays the following in the ”Component Details” multiline:

UOM

The production unit of measure of the item. The system retrieves the UOM for the item, variant and Organization Unit combination from the “Item Administration” business component.

Scrap %

The effective scrap of the input item expressed as percentage. The system displays “100%” by default on launch of the page. If the scrap is specified, it should be between “0” and “100”.

PP Seq.

The sequence number identifying the position in the process plan of the activity associated with each item. The number also defines the order in which the activities are to be performed.

 

Help facility available.

The system displays the following in the ”Component Details” multiline:

Plant

The plant of the warehouse where the item is identified. The plant corresponding to the warehouse gets displayed.

Warehouse Code

The code identifying the warehouse where the issues for the input items are made.

 

Help facility available.

Setup Qty.

The quantity required during the setup sub-activity of an item. The system displays the quantity defined for the item in the product structure. If the setup quantity is entered, then it should be greater than or equal to zero. For Phantom Items, the setup quantity should be zero.

Batch Qty.

The quantity required during the batch sub-activity of an item. The system displays “0.0” by default on launch of the page. If the batch quantity is entered, then it should be greater than or equal to zero. For Phantom Items, the batch quantity should be zero.

The system displays the following in the ”Component Details” multiline:

Item Type

The type of the selected item.

I/O

Use a drop-down list box to indicate whether an item is an input, output or tool item.

 
  • Input – indicates an input item.

 
  • Output – indicates a secondary output item.

 
  • Tool – indicates a phantom item.

Valid From

The date from which an item is valid based on the condition. If the date is specified, it should be in correct date format. If the date is not specified, then the system displays “Low Date” (the earliest date set in the system parameters)as the default date. The valid from date should be lesser than the valid to date.

Valid To

The date till which an item is valid based on the condition. If the date is specified, it should be in correct date format. If the date is not specified, then the system displays “High Date” (the latest date set in the system parameters) as the default date.

Min. Qty.

The minimum quantity attached to the item. If the minimum quantity is specified, then it should be greater than zero. If the quantity is not specified, then the system displays “Low Quantity” (the bottom limit set in the system parameters) as the default quantity.

Max. Qty.

The maximum quantity attached to the item. If the maximum quantity is specified, then it should be greater than zero. If minimum and maximum quantity is specified, then this field should be less than maximum quantity. If the quantity is not specified, then the system displays “High Quantity” (the upper limit set in the system parameters) as the default quantity.

Ref. Designator

Indicates the reference designators used for identification purposes. Reference designators may be used for locating the position or the unit to which a part belongs.

Lead Time Offset

The lead-time offset indicates the time at which the item is required from the beginning of the first activity. The system displays “0.0” by default on launch of the page.

Stock Status

Use the drop-down list box to select the stock status of the input item. The system displays “Accepted” by default on launch of the page.

 
  • Accepted – indicates the accepted items

 
  • Rejected  - indicates the rejected items

Critical

Use the drop-down list box to indicate whether an item is critical or not. You can select from “Yes” or “No”. The system displays “No” by default on launch of the page.

Use-Up Option

Use the drop-down list box to indicate whether the items are to be replaced or not. You can select from “Yes” or “No”. The system displays “No” by default on launch of the page.

Repl. Item Code

The code identifying the item that will replace the specified input item.

Repl. Variant Code

The code or number identifying the item variant of the replacement item.

Seq. Desc.

The description of the position sequence of the item.

The system deletes the sequence details for the specified product structure and selected PS sequence number and refreshes the screen.

The system ensures that the login user has “Modify” or “All” access permission to the "Maintained by" control unit of the PS number. If there are no permissions then an error message is displayed.

The system checks the status of the product structure. If the status has been changed from "Draft” to “Active”, then the system executes all validations and updates the PS status to “Active”. If the status is changed from “Active” to “Inactive”, then the system updates the PS status to “Inactive". If the status is changed from “Inactive” to “Active”, then the system executes all the validations and updates the PS status to “Active”.

The system ensures that at least one row in the multiline should be present. This check is made even in the cases where the rows are marked for deletion. After deletion, there should exist at least one row. The system saves and updates the product structure details.

To proceed, carry out the following

The login user ID and the system date are updated in the “Created By”, “Created Date”, “Edited By” and “Edited Date” fields.

The system displays the following:

Created By

The login user ID of the person who has created the product structure.

Created Date

The date on which the product structure was created.

Edited By

The login user ID of the person who has edited the product structure.

Edited Date

The date on which the product structure was edited.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Edit Product Structure – An overview      

Activity overview

This page provides the help facility to search the product structure for which you can modify or delete the details.

In order to modify  the details of a product structure, you have to enter the code that identifies the product structure or can make use of the help screen.  On entering the details in the help screen the system retrieves the corresponding results in the multiline. Once the details are retrieved, you can modify the item and variant together with the fields in the multiline. You can define different input or the secondary output items with the warehouse and plant, quantity and yield, setup and batch quantity, validity dates and quantities, offset time and the criticality of the item. Different position numbers are assigned to the newly added input items and its variants.

This activity also allows you to delete the input items and secondary output items of the product structure. You can delete multiple primary item details using this page. Once the details are retrieved in the multiline, you can select the records containing the input item details and initiate the delete operation. Once the items are deleted the changes gets updated permanently and the product structure is treated as deleted only when the status is changed to ”Inactive”.