Specify Receipt List

Unified Glossary

Basics of using Ramco Enterprise series web page

Using online help

This page allows you to specify the list of items to be received from the supplier after the completion of the subcontracting process. Tell me more

The “Specify Receipt List” page appears

The system displays the following details in the header

Status

The status of the SCO

SCO No.

A unique code identifying the SCO

Amendment NO.

A unique code identifying the amendment done to the SCO.

Competitive Bidding

Displays whether the Subcontract Order supports competitive bidding

Supplier Code

The code identifying the supplier

Name

The name of the supplier

 

Zoom facility available

Type

The type of the SCO. The possible values are Conversion, Activity and Service

SCO Line No.

Use the drop-down list box to select the line number of the item in the SCO document. The drop-down lists all the line numbers in the SCO. The lowest of all the SCO line numbers is set as the default value

The system displays the following fields in the “Item Details” group box

BOM Code

The unique code identifying the Bill Of Material (BOM) which defines all the constituent items and their quantities required to manufacture the item

Item Code

The unique code identifying the line item in the SCO

Variant Code

The variant of the item

Desc.

The textual description of the item

Qty.

The number of units of the line item requested in the SCO

UOM

The unit of measurement of the item

BOM Applicable in other UOM

Displays whether the BOM is applicable in other UOM

Receipt At

Use drop down box to select the OU in which the Items are to be received from the Supplier. The drop-down lists active “GR OU” that are mapped to the “Purchase Order” component that also belongs to the same financial company and the business unit as the SCO OU

Warehouse Code

The code identifying the warehouse where the subcontract items are stored. (Alphanumeric, 10)

 

Help facility available

Receipt Date

The date on which the required quantity must be delivered (Date Format). Mandatory. The receipt date must be greater than or equal to the current date and the SCO date.

Item Flow

Use the drop down box to select the type flow. The different types of flow that is possible is

 
  • Primary Output – Indicates that the item is the primary output. This is normally the item which is subcontracted

 
  • Secondary Output – Indicates that the item is the byproduct of the subcontract activity

 
  • Returnable Output – Indicates that the line item is a returnable item. Which is normally issued to the subcontractor when the work is started. This is normally one of the issuable inputs

Item Code

The unique code identifying the item which has to be returned with the subcontracting item specified as a line item in the SCO document (Alphanumeric, 32) Mandatory

 

Help facility available

Variant

The variant of the item code., (Alphanumeric, 8)

Receipt Qty

The quantity of items to be received from the supplier  (Integer). This should be a positive value

 

Receipt Qty = Subcontract item order quantity (as specified in the SCO)/ Subcontract item Qty in the BOM  * Receipt Item quantity as per BOM if the “Prop Qty for SCI” is “YES”. If the “Prop Qty for SCI” is “NO” then the receipt qty is the same as the “Receipt Item Qty” defined in the BOM

UOM

The unit of measurement of the item (Alphanumeric, 10)  

 

Help Facility Available

Receipt At

Use drop down box to select the OU in which the Items are to be received from the Supplier. The drop-down lists active “GR OU” that are mapped to the “SCO” component that also belongs to the same financial company and the business unit as the SCO OU

Warehouse

The code identifying the warehouse where the subcontracted items are stored. (Alphanumeric, 10)

 

Help facility available

Receipt Date

The date on which the required quantities are to be received  (Date Format). Mandatory. The receipt date must be greater than or equal to the current date and the SCO date.

Tolerance % (+ve)

The excess tolerance percentage, which can be received for the item. (i.e.) the percentage of items that can be received in excess of the quantity specified (Integer). This should not be negative value.

 

Example:  if the positive tolerance percentage is 5% and if the quantity of items that is received is 60. Then an excess of 3 items can be received and not beyond that

Tolerance % (-ve)

The shortage tolerance percentage, which can be received for the item (i.e.) the percentage of items that can be received in short of the quantity specified (Integer). This should not be negative value.

 

Example:  if the negative tolerance percentage is 5% and if the quantity of items that is received is 60. Then 3 items short of the total quantity can be received and not less than that

The system displays the following fields in the “Issue Details” Group box

Proportional qty for SCI

The proportional quantity of the item to be received with respect to the Subcontract line item

Change allowed

This field can assume two values

 
  • Yes – If the quantity is modifiable

 
  • No – if the quantity is not modifiable

Item Description

The textual description of the item is displayed

The receipt list is saved to the SCO document

The status of the SCO is set to the level in the multilevel authorization to which the Login Id belongs

Example: The status of the SCO is set to “Level 1” if the login Id corresponds to the first level”

The status of the SCO is set to “Level 1/3” if the login Id corresponds to one of the three persons in a committee

The status is set to “Open” if the approver belongs to the one and only level or the final level in the authorization profile if the LOI field is not checked else the status is set to “Approved LOI”

To proceed, carry out the following

Top

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specify Receipt List – An Overview

Activity Overview

The list of receivable items can be specified for each Subcontract Order (SCO) line item.

The page displays all the SCO details such as the SCO number, amendment number, and type of SCO. This page displays all the supplier details like the supplier code and the supplier name. On giving the SCO line number, the system displays all the item details such as the item code, variant of the item, description of the item, the OU where the item is to be received and the Bill Of Material (BOM) code for the line item

The item specified in the receipt list multiline can be classified as primary output, secondary output and returnable input. The primary output is the main item that is supplied by the supplier. This is normally the item on which subcontracting service is performed. The secondary output is the byproduct that arises in the subcontract process. The returnable inputs are the item that are supplied to the subcontractor to carry forward the subcontract activity and which needs to be returned upon completion of the work.

For each receivable item you can specify the item details such as the item code, variant, receipt quantity, the UOM of the item, the OU where the items are received, the warehouse where the items are stored,

You can also approve the SCO in this page

Top